ebaircontrol.com
Air Mixer provides a full solution to reducing air stratification in the plenum and coil freeze-ups. The design was conceptualized by looking at the existing problems and devising solutions that best fit the market requirement at an affordable cost. Various programs were used and were studied to see what design and size worked the best.
BENEFITS OF AHU MIXER
Few principles were considered,
Layer by layer meshing of two gradients of air across the full plenum.
Effectively churning the air within the Plenum/ box itself without requiring additional space
Optimizing the flow field with a high ratio of mixing per unit of air.
Energy savings
PROBLEMS OF AIR STRATIFICATION/FREEZE-UPS/FAILURES
In the HVAC Air Handling system, air stratification resulted from the improper design inherent in moving air streams by keeping air streams of different air temperatures from mixing effectively for a long distance. As a result, it was exceedingly difficult to effectively operate an Air handler as well maintaining the Indoor air quality.
In the winter because of no mixing, coils often got frozen, which damaged the coil as well causing freeze stat trips and sensing errors. In summer, both streams of air were not mixed properly causing additional load on the heat transfer coils leading to large energy bills. Over time the air mixing problem became a serious matter as Outdoor air percentage started increasing as a result of the mandate IAQ requirement. Read More
Social
N/A
App
Category
heavy_industry_and_engineering/construction_and_maintenance
Monetization
Unknown
Domain Information
WHOIS
Date
Created
2007-07-31
Nameservers
ams-ns1.greengeeks.com
chi-ns1.greengeeks.com
chi-ns2.greengeeks.com
DNS Records
A
198.72.127.235
CA
iWeb Technologies Inc
MX
ebaircontrol-com.mail.protection.outlook.com
Microsoft Outlook
TXT
lld82an4grn8sk2hfpqdin6dfe
MS=ms22387854
v=spf1 ip4:198.72.127.235 include:spf.greengeeks.net include:secureserver.net -all
Site Overview
Site Engagments
46.73%
Bounce Rate
Pages Per Visit
2
Total Visits
3.8K
Time on Site
00:00:28
Traffic Sources
Social
9.85%
Paid
1.25%
Mail
0.09%
Referrals
6.05%
Search
52.14%
Direct
30.53%
Traffic Top 5 Country
87.86%
12.14%
Review Score
UnknownGoogle Ads Overview
No ads shown in the past year.
Google SEO Overview
Top 5 Keywords (US)
negative pressure room
hvac bypass duct
hvac bypass
bypass duct hvac
induction air conditioner
Top 5 Pages (US)
TopKeywordnegative pressure room
TopKeywordhvac bypass duct
TopKeywordinduction air conditioner
TopKeyworddampers
TopKeywordventuri valve
Google Indexing Results Overview(About Unknown Results)
Posts
| Title | Author | View | Comments | Last Update |
|---|